XNX-AMSI-NNNNN
Product Description
XNX is an extremely flexible transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies. It can also be configured to provide a wide variety of industry standard output signals. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed, to most effectively address the different gas detection applications on site.
Flexible
• Compatible with all Honeywell Analytics gas sensors
• Allows selection of best sensor technology for each application
• Choice of all industry standard output signals
• Ability to adapt configuration as site needs change
• Future-proofed for any new output standardsCommon Transmitter Platform
• Simplified and reduced cost of installation
• Reduced training time and cost
• Less chance of misinterpreting messages
• Less chance of incorrectly changing settings
• Reduced maintenance, spares, stock and costEasy to Use
• Easy read multilingual backlit LCD with text, bar graph, digits and icons
• Local or remote sensor mounting options
• Selectable sink, source or isolated 4-20mA output to suit preferred wiring topology
• HART® communications as standard for remote diagnostics/configurationReduced Operational Costs
• Fully configurable via non-intrusive magnetic switches
• No hot work permit needed
• Hot swap toxic and Oxygen sensor cartridges
• Serviceable catalytic and IR sensors
• Auto-inhibit during maintenanceFriendly Installation
• Integral surface mounting lugs or optional pipe or ceiling mounting brackets
• 5 x M25 or ¾" NPT cable/conduit/sensor entries
• Plug-in 'POD' module removes to give access to terminal area
• Removable plug/socket type terminal blocks for ease of wiringTypical Applications
• Offshore oil and production platforms
• Oil and gas exploration and drilling
• Refineries
• Chemical and petrochemical plants
• Onshore oil and gas terminals
• Gas transmission
• Power stations
Gas | Cartridge P/N | Selectable FullScale Range | DefaultRange | Lower Detectable Limit | Steps | Selectable Cal Gas Range | DefaultCal Point | ResponseTime(T50) sec | ResponseTime(T90) sec | Accuracy | Operating TemperatureMin Max | |||
O2 | Oxygen | XNXXSO1SS | n/a | 25.0 %Vol | 3.5 %Vol | n/a | 20.9 %Vol (Fixed) | 20.9 %Vol | T20 <10 | <30 | <+/-0.6 %Vol | -30°C / -34°F | 55°C / 131°F | |
H2S (LoLo) | Hydrogen Sulphide | XNXXSH3SS | n/a | 15.0ppm | 1.0ppm | n/a | 30 to 70% of selected ful l scale range | 10ppm | <20 | <40 | <+/-0.3ppm | -40°C / -40°F | 55°C / 131°F** | |
H2S (Lo) | Hydrogen Sulphide | XNXXSH1SS | 10.0 to 50.0ppm | 15.0ppm | 1.0ppm | 0.1ppm | 10ppm | <20 | <30 | <+/-0.3ppm | -40°C / -40°F | 55°C / 131°F** | ||
H2S (Hi) | Hydrogen Sulphide | XNXXSH2SS | 50 to 500ppm | 100ppm | 1ppm | 10ppm | 50ppm | <20 | <30 | <+/-5ppm | -40°C / -40°F | 55°C / 131°F** | ||
CO | Carbon Monoxide | XNXXSC1SS | 100 to 500ppm | 300ppm | 5ppm | 100ppm | 100ppm | <15 | <30 | <+/-2ppm | -40°C / -40°F | 55°C / 131°F** | ||
SO2 (Lo) | Sulphur Dioxide | XNXXSS1SS | 5.0 to 20.0ppm | 15.0ppm | 0.6ppm | 5.0ppm | 5.0ppm | <15 | <30 | <+/-0.3ppm | -40°C / -40°F | 55°C / 131°F** | ||
SO2 (Hi) | Sulphur Dioxide | XNXXSS2SS | 20.0 to 50.0ppm | 50.0ppm | 1.5ppm | 10.0ppm | 25ppm | <15 | <30 | <+/-0.6ppm | -40°C / -40°F | 55°C / 131°F** | ||
NH3 (Lo) | Ammonia | XNXXSA1SS | 50 to 200ppm | 200ppm | 6ppm | 50ppm | 100ppm | <60 | <180 | <+/-4ppm | -20°C / -4°F | 40°C / 104°F | ||
NH3 (Hi) | Ammonia | XNXXSA2SS | 200 to 1,000ppm | 1,000ppm | 30ppm | 50ppm | 300ppm | <60 | <180 | <+/-20ppm | -20°C / -4°F | 40°C / 104°F | ||
CL2 (Lo) | Chlorine | XNXXSL2SS | n/a | 5.00ppm | 0.15ppm | n/a | 2.0ppm | <20 | <60 | <+/-0.2ppm | -10°C / 14°F | 55°C / 131°F | ||
CL2 (Hi) | Chlorine | XNXXSL1SS | 5.0 to 20.0ppm | 5.0ppm | 0.6ppm | 5.0ppm | 2.0ppm | <20 | <30 | <+/-0.2ppm | -10°C / 14°F | 55°C / 131°F | ||
CIO2 | Chlorine Dioxide | XNXXSX1SS | n/a | 1.00ppm | 0.03ppm | n/a | 0.5ppm | <30 | <120 | <+/-0.03ppm | -20°C / -4°F | 55°C / 131°F | ||
NO | Nitrogen Monoxide | XNXXSM1SS | n/a | 100ppm | 3ppm | n/a | 50ppm | <15 | <30 | <+/-2ppm | -20°C / -4°F | 55°C / 131°F | ||
NO2 | Nitrogen Dioxide | XNXXSN1SS | 5.0 to 50.0ppm | 10.0ppm | 1.5ppm | 5.0ppm | 5ppm | <15 | <30 | <+/-0.2ppm | -20°C / -4°F | 55°C / 131°F | ||
H2 (Lo) | Hydrogen | XNXXSG1SS | n/a | 1,000ppm | 30ppm | n/a | 500ppm | <60 | <90** | <+/-8ppm | -20°C / -4°F | 55°C / 131°F | ||
H2 (Hi) | Hydrogen | XNXXSG2SS | n/a | 10,000ppm | 300ppm | n/a | 5000ppm | <15 | <30 | <+/-150ppm | -20°C / -4°F | 55°C / 131°F | ||
HF | Hydrogen Fluoride | XNXXSF1SS | n/a | 12.0ppm | 0.4ppm | n/a | 5.0ppm | 120 | <240 | <+/-0.5ppm | -20°C / -4°F | 55°C / 131°F | ||
PH3 | Phosphine | XNXXSP1SS | n/a | 1.20 ppm | 0.04ppm | n/a | 0.5ppm | <15 | <30 | <+/- 0.02ppm | -20°C / -4°F | 40°C / 104°F | ||
HCN | Hydrogen Cyanide | XNXXSY1SS | n/a | 30.0ppm | 1.0ppm | n/a | 10.0ppm | <35 | <200 | 0.4ppm | -20°C / -4°F | 55°C / 131°F | ||
F2 | Fluorine | XNXXSU1SS | n/a | 4.00ppm | 0.36ppm | n/a | 2.00ppm | <5 | <30 | 0.03ppm | -20°C / -4°F | 55°C / 131°F | ||
O3 | Ozone | XNXXSZ1SS | n/a | 0.400ppm | 0.032ppm | n/a | 0.200ppm | <15 | <60 | 0.003ppm | -20°C / -4°F | 55°C / 131°F | ||
ETO | Ethylene Oxide | XNXXSE1SS | 20.0 to 50.0ppm | 25.0ppm | 1.0ppm | 5.0ppm | 10.0ppm | <40 | <125 | 0.3ppm | -20°C / -4°F | 55°C / 131°F |
XNX Multi Purpose Detector (MPD)
Sensor Type | Target Gas | User SelectableFull Scale Range | Default Range | Steps | User SelectableCal Gas Range | Primary Cal Gas | Default Cal Point | ResponseTime (T90) secs | Accuracy | Operating TemperatureMin Max | |||||||||||
IR CO2 | Carbon Dioxide | 1.00 to 5.00%Vol | 5.00%Vol | 1.00%Vol | 1.50 to 3.5%Vol | Carbon Dioxide | 2.5%Vol | <60 | ±5% of FS | -20°C/-4°F | +50°C/+122°F | ||||||||||
IR CH4 | Methane | 1.00 to 5.00%Vol | 5.00%Vol | 1.00%Vol | 1.50 to 3.5%Vol | Methane | 2.5%Vol | <30 | ±5% of FS | -20°C/-4°F | +50°C/+122°F | ||||||||||
20 to 100%LEL | 100%LEL | 10%LEL | 30 to 70%LEL | 50%LEL | ±5% of FS | ||||||||||||||||
IR HC | Hydrocarbons# | 20 to 100%LEL | 100%LEL | 10%LEL | 30 to 70%LEL | Propane | 50%LEL | <30 | ±5% of FS | -20°C/-4°F | +50°C/+122°F | ||||||||||
Catalytic | Flammables | 20 to 100%LEL | 100%LEL | 10%LEL | 30 to 70%LEL | Methane | 50%LEL | <30 | ±5% of FS | -40°C/-40°F | +65°C/+149°F |
NOTES:
Data taken at ambient conditions of 20°C, 50% RH. Data represents typical values of freshly calibrated sensors without optional accessories attached. *Accuracy at 10% of default full scale (typical A1 alarm) of applied gas, or minimum (whichever is greater). Measured using calibration flow housing at calibration flow rate. Performance figures are applicable between 10 and 90% of full scale. Performance figures are measured by test units calibrated at 50% of full scale.
**Accuracy for operation between -20°C and -40°C is +/-30% of applied. Operation at these temperatures continuously (exceeding 12 hours) may cause deterioration in sensor performance and shorten sensor life.
# Propane sensor with linear cross reference for Ethylene, n Butane and n Pentane. Contact Honeywell Analytics for any additional data or details.
BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.
Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10, 000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.
It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.
The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.
BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: Magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.
History of BNSENS Company:
BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.
1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.
2002: The company expanded its product line and launched temperature sensors
2005: Started producing high-precision pressure sensors for the test and measurement market
2006: Became an official authorized agent of Honeywell
2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved
2010: Became a supplier of Emerson
2011: We started selling SICK sensors
2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC
2015: Cooperated with Siemens in Vietnam
2017: The factory moved to Nanjing High-tech Zone
2019: Became a national high-tech enterprise in China
2023: We started selling products from Infineon and Rohm
BNSENS, The Future Starts Here.