Flow Sensor Guide

BFM0200 Gas Flow Sensor
s1
Performance index· Supply Voltage: 24V DC· Flow range: 0~3L/min· Pressure range: -100KPa ~ 200KPa· Accuracy: ±3% (read)· Interfaces: Analog signal 1~5V DC· Advantage: Compact, simple design, Quick response and quick recovery time,Excellent long-term stability


BFM3000 Gas Flow Sensor
s1
Performance index· Supply Voltage: 4.75-5.25V DC· Measuring range: -200~+200SLM· Operating temperature: 0~50℃· Accuracy: ±1.5% read (Typical)· Repeatability: ±0.5% read (Typical)· Interfaces:Digital I2C· Advantage: Full calibration, temperature compensation;Low pressure loss, fast response, small zero drift


BMS2106 Mass Gas Flow Sensor
s1
Performance index· Supply Voltage: Three AA batteries / 9-24V DC· Flow range: 0 - 200L/min (standard)· Maximum working pressure: 0.8MPa· Accuracy: ±3%FS· Standard calibration gas: Air (standard condition)· Interfaces: RS485· Communication: Modbus-RTU· Advantage: Mass flow and temperature integrated measurement, support a variety of aas measurement


BAFS3000 Mass Gas Flow Sensor
s1
Performance index· Supply voltage: 8~24V DC· Temperature range: -25C~+85℃· Flow range: 0 ~ 2500 sccm· Withstand voltage: 0.3MPa· Accuracy: 1.5%F.S· Resolution: 01%· Output signal: 1~5 V or I2C or RS485· Zero drift: 0.2%Year· Advantage: Linear output and no temperature compensation required


BAFS4000 Mass Gas Flow Sensor
s2
Performance index· Supply voltage: 8~18V DC· Temperature range: -25℃ ~+85℃· Flow range: 0~300 SLPM· Response time: 20ms· Accuracy: 1.5%F.S· Resolution: 0.1%F.S· Output signal: 1~5 V or I2C· Zero drift: 0.2%F.S· Advantage: Linear output and temperature compensation: Positive and negative gas flow measurement


BAFS4000B Mass Gas Flow Sensor
s3
Performance index· Supply voltage: 8~18V DC· Temperature range: -25℃ ~+85℃· Flow range: 0~300 SLPM· Response time: 20ms· Accuracy: 1.5%F.S· Resolution: 0.1%F.S· Output signal: 1~5 V or I2C· Zero drift: 0.2%F.S· Advantage: Linear output and temperature compensatior Maintain long term stability with minimum zero drift


BAFS5008 Mass Gas Flow Sensor
s4
Performance index· Supply voltage: 8~24VDC,50mA· Temperature range: -25℃~+85℃· Flow range: 20/50/100/200 slpm (customizable)· Response time: 20ms· Accuracy: 1.5%F.S· Maximum pressure: 0.8MPa (customizable)· Output signal: 1~5 V or I2C· Interface: G3/8 (customizable)· Advantage: Linear output and no temperature compensation; Maintain long term stability with minimum zero drift


BAFS5012 Mass Gas Flow Sensor
s5
Performance index· Supply voltage: 8~24VDC,50mA· Temperature range: -25℃~+85℃· Flow range: 20/50/100/200 slpm (customizable)· Response time: 65ms· Accuracy: 1.5%F.S· Maximum pressure: 0.8MPa (customizable)· Output signal: 1~5 V or I2C· Interface: NPT1/2· Advantage: Linear output and no temperature compensation; Maintain long term stability with minimum zero drift


BAFS5019A Mass Gas Flow Sensor
s6
Performance index· Supply voltage: 8-24VDC,50mA· Temperature range: -25C ~+85℃· Flow range: 0-300/500/600/800/1000 slpm· Response time: 20ms· Accuracy: ±1.5%FS· Maximum pressure: 0.8MPa (customizable)· Communication mode: I2C/RS485(MODBUS· Interface: G3/4 (customizable)· Advantage: Linear output and no temperature compensation; waintain long term stability with minimum zero drift


BFD2000 Liquid Flow Sensor
s7
Performance index· Supply voltage: 12V DC· Temperature range: 5℃-70℃· Flow range: 2.5 - 20L/min· Response time: 1s· Accuracy: ±3%RD· Output signal: RS485· Advantage: Small volume, easy to install and use;Full range high stability and excellent repeatability


BMS1000 Mass Flowmeter
s8
Performance index· Supply voltage: 9~24V DC· Measuring range: 0-200 0- 20 / 0-2(L/min)· Accuracy: +4%RD (2≤x<50L/min) ±2%RD (50≤x<200L/min)+4%RD (0.2≤x<5L/min) +2%RD (5≤x<20L/mim)+4%RD(0.02≤x<0.5L/min 2%RD (0.2≤x<5L/min)· Output mode: RS485, 2 NPN collector open circuitoutput, analog output (1-5V/4-20mA, choose one of two)· Advantage: Support a variety of gas measurementIntegrated mass flow and temperature measurement


BFM0725 Mass Flowmeter
s9
Performance index· Supply voltage:9 - 24V DC· Measuring range: 0- 25L/min· Accuracy: ±3%F.S· Temperature range: 0℃-50℃· Communication mode: RS485· Max working pressure: 0.8MPa· LcD display· Advantage: Integrated measurement of mass flow and temperature


BMC1000 Mass Flow Controller
s10
Performance index· Supply voltage: 24V DC· Working current: < 400mA· Typical power: 6.5W@24V· Flow range: 0- 200L/min· Accuracy: ±3%FS· Communication mode: RS485 (Modbus-RTU)· Measuring gas: Air, nitrogen, argon, carbon dioxide, elium, oxygen· Advantage: Good repeatability, stable and reliable; LCD screen displays monitoring control


BMC2000 Mass Flow Controller
s11
Performance index· Supply voltage: 24V DC· Working current: < 120mA· Typical power: 2W@24V· Flow range: 0 - 100mL/min· Accuracy: ±3%FS· Communication mode: RS485/analog woltage· Measuring gas: Air, nitrogen, argon, carbon dioxide,helium, oxygen· Advantage: Mass fow and temperature integrated measurement monitoring control


  